TM 9-4910-663-34
f.
Removal and Replacement of Stationary Driven Varidisc Assembly (fig 3-5).
(1)
Remove the varidrive assembly from the test stand. Refer to paragraph 2-19.
(2)
Remove the input shaft rear bearing. Refer to paragraph 3-19e.
(3)
Remove six screws (51) and lockwashers (52) from each side plate cover (50) and remove both side plate
covers.
(4)
Mark carefully the axial and radial position of stationary driven varidisc assembly (100) in relation to input
shaft (98). (See fig 3-4.)
(5)
Loosen the four clamping screws on the split hub of stationary driven varidisc assembly (100), alternating
on the clamping screws carefully, until spring assembly (97) is relaxed or fully extended.
WARNING
When the four clamping screws are loosened, stationary driven varidisc assembly (100) may have
a tendency to slide back on input shaft (98) because of spring tension; therefore, ascertain that the
varibelt is at the outermost position of the stationary driven varidisc assembly to relieve the spring
tension.
(6)
Loosen the four clamping screws on the split hub of stationary driven varidisc assembly (100) completely,
and slide the stationary driven varidisc assembly off input shaft (98).
(7)
Reverse the procedures of steps (1) through (6) to install the replacement stationary driven varidisc
assembly.
g.
Removal and Replacement of Adjustable Driven Varidisc Assembly (fig 3-5).
(1)
Remove the stationary driven varidisc assembly. Refer to paragraph 3-19f.
(2)
Move varibelt (49) back and over the end of input shaft (98).
(3)
Slide adjustable driven varidisc assembly (99) off input shaft (98).
(4)
Reverse the procedures of steps (1) through (3) to install the replacement adjustable driven varidisc
assembly.
3-42