TM 9-4910-663-34
2-22.
REMOVAL AND INSTALLATION OF BLOWER MOTOR ASSEMBLY (fig 2-10)
a.
Disconnect main power from the test stand.
b.
Remove the load bank assembly from the test stand. (Refer to paragraph 2-16.)
c.
Remove the retaining hardware that attaches the blower motor assembly to its support bracket.
d.
Rotate the rear of the blower motor carefully toward the rear of the test stand.
e.
Loosen the two screws that secure the connection cover to the blower motor, and swing the connection cover
open.
f.
Unsnap the two wires from the blower motor.
g.
Remove the blower motor assembly from the test stand.
h.
Reverse the procedures of steps a through g to install the blower motor assembly in the test stand.
Change 1 2-74