TM 9-4910-663-34Table 2-2. Preliminary Control SettingsControlReferenceDesignationPositionINSTRUMENT PANEL (fig 2-4)DC AMMETER LOAD & STARTER OUTPUT CURRENTS14LOAD X10BATTERY CHART CURRENT RANGE switchDC AMMETER LOAD & STARTER OUTPUT CURRENTS15OffBATTERY CHARGE CURRENT PRESS FOR BAT-TERY CHARGE RATE switchDC AMMETER FIELD CURRENT RANGE switchS30X6MILLIVOLT METER MILLIVOLT DROP RANGES16X10switchMILLIVOLT METER MILLIVOLT DROP PRESSS34OffTO READ switchDC VOLTMETER OUTPUT VOLTAGE RANGES12X5switchDC VOLTMETER OUTPUT VOLTAGE SELECTS11REC GEN (P/Nswitch7458-2)EXT (P/N7458-4)TACHOMETER RPM SELECT switchS36DIRECT DRIVETACHOMETER RPM PULLEY CALIBRATIONR35Fully ccwcontrolAC AMMETER OUTPUT CURRENT SELECTS25T1switchAC AMMETER OUTPUT CURRENT RAINCES26X5switchAC VOLTMETER OUTPUT VOLTAGE SELECTS28CIRCUIT T1-switchT2AC VOLTMETER OUTPUT VOLTAGE RANGES27X2switchCONTROL PANEL (fig 2-5)EXTERNAL FIELD EXCITER AC SYSTEMS switchS31OFFGENERATOR FIELD switchS37INT GNDPOLARITY REVERSING switchS7NEG GNDFIELD CIRCUIT switchS32OFFFINE CONTROL 0-5 AMPS (MAX) switchS29OFFFIELD CURRENT control (fine)R27Fully ccwFIELD CURRENT 0-20 AMPS (MAX) controlR26Fully ccwCIRCUIT BREAKERSCB2 throughINCB11BATTERY CIRCUIT SELECTOR switchS6OFF (fullycw)REGULATOR CHECK FIXED RESISTANCE METHODS13OFFswitchDC VARIABLE VOLTS switchS10OFF2-8Change 1Change 12-8.1/(2-8.2 blank)