TM 9-4910-663-34
Table 2-2. Preliminary Control Settings
Control
Reference
Designation
Position
INSTRUMENT PANEL (fig 2-4)
DC AMMETER LOAD & STARTER OUTPUT CURRENT
S14
LOAD X10
BATTERY CHART CURRENT RANGE switch
DC AMMETER LOAD & STARTER OUTPUT CURRENT
S15
Off
BATTERY CHARGE CURRENT PRESS FOR BAT-
TERY CHARGE RATE switch
DC AMMETER FIELD CURRENT RANGE switch
S30
X6
MILLIVOLT METER MILLIVOLT DROP RANGE
S16
X10
switch
MILLIVOLT METER MILLIVOLT DROP PRESS
S34
Off
TO READ switch
DC VOLTMETER OUTPUT VOLTAGE RANGE
S12
X5
switch
DC VOLTMETER OUTPUT VOLTAGE SELECT
S11
REC GEN (P/N
switch
7458-2)
EXT (P/N
7458-4)
TACHOMETER RPM SELECT switch
S36
DIRECT DRIVE
TACHOMETER RPM PULLEY CALIBRATION
R35
Fully ccw
control
AC AMMETER OUTPUT CURRENT SELECT
S25
T1
switch
AC AMMETER OUTPUT CURRENT RAINCE
S26
X5
switch
AC VOLTMETER OUTPUT VOLTAGE SELECT
S28
CIRCUIT T1-
switch
T2
AC VOLTMETER OUTPUT VOLTAGE RANGE
S27
X2
switch
CONTROL PANEL (fig 2-5)
EXTERNAL FIELD EXCITER AC SYSTEMS switch
S31
OFF
GENERATOR FIELD switch
S37
INT GND
POLARITY REVERSING switch
S7
NEG GND
FIELD CIRCUIT switch
S32
OFF
FINE CONTROL 0-5 AMPS (MAX) switch
S29
OFF
FIELD CURRENT control (fine)
R27
Fully ccw
FIELD CURRENT 0-20 AMPS (MAX) control
R26
Fully ccw
CIRCUIT BREAKERS
CB2 through
IN
CB11
BATTERY CIRCUIT SELECTOR switch
S6
OFF (fully
cw)
REGULATOR CHECK FIXED RESISTANCE METHOD
S13
OFF
switch
DC VARIABLE VOLTS switch
S10
OFF
2-8
Change 1
Change 1
2-8.1/(2-8.2 blank)