TM 9-2510-247-13&P
0028 00
UNIT TROUBLESHOOTING - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
HYDRAULIC SYSTEM - Continued
3. CANNOT RELIEVE HYDRAULIC PRESSURE FROM ONE OR MORE LEVERS
Step 1.
Is hydraulic breather valve in CLOSED position (WP 0021)?
If no, go to step 2.
If yes, move breather valve to OPEN position (WP 0021).
Step 2.
If yes, clean or replace return line.
4. CYLINDERS DO NOT EXTEND OR RETRACT WHEN PUSH SWITCH ON ELECTRIC CONTROL
Step 1.
Are hydraulic motors running and hydraulic pressure being maintained?
If no, check to see if there is voltage at push button switch and solenoid.
If yes, adjust hydraulic flow control valves (WP 0003).
5. HYDRAULIC FLUID COMING FROM BREATHER VALVE
Step 1.
If no, adjust oil level (WP 0056) and ensure breather valve on top of reservoir is
open at all times.
Step 2.
Is hydraulic pressure gauge showing pressure?
If yes, go to step 2.
0028 00-2