TM 9-2510-247-13&P
0059 00
REMOVAL - Continued
CAUTION
When connecting a hose to a fitting, always use two wrenches. Use one
wrench to turn the swivel nut onto the fitting, and use another wrench to
keep the hose from rotating. If the hose rotates, it can loosen the other end
of the hose or loosen the fitting at the other end.
NOTE
Tag all hoses and fittings prior to disconnecting to ease installation.
Hydraulic hoses must be capped and/or plugged when disconnecting to
1.
Disconnect ten hydraulic hoses (3) from elbows (4).
2.
Loosen swivel nut at opposite end of hydraulic hose (5).
3.
Disconnect hydraulic hose (5) from tee pipe (6)
4.
Disconnect hydraulic hose (7) from straight adapter (8).
5.
Remove screw (9) and ground wire (10) from main valve assembly.
6.
Remove two screws (1) from solenoid cover (2) and remove solenoid cover (2) from main
valve assembly.
NOTE
Tag all electrical wires prior to disconnecting to ease installation.
7.
8.
Remove straight adapter (8) from main valve assembly (13).
9.
Remove plug (17) from main valve assembly (13).
10. Remove ten elbows (4) from main valve assembly (13).
11. Remove four flow restrictor valves and springs (18) from main valve ports (19).
12. Remove two screws (11) and lockwashers (12). Discard lockwashers.
13. Remove main valve assembly (13) from frame.
14. Remove pressure gauge (14) from straight adapter (15).
15. Remove straight adapter (15) from tee pipe (6).
0059 00-2