TM 9-2510-247-13&P
0050 00
BATTERY REMOVAL - Continued
CAUTION
Battery negative (-) ground cables must be removed prior to positive (+) cables.
2.
Remove negative (-) nylon stud nuts (6 and 7) and remove two cables (8) from Battery A and
one cable (8) from Battery B.
3.
Remove positive (+) nylon stud nuts (3 and 4) and remove two cables (5) from Battery A and
three cables (5) from Battery B.
4.
Replace stud nuts on batteries and lift batteries from battery box.
Figure 94. Battery Box Assembly
BATTERY INSTALLATION
1.
Position batteries in battery box.
2.
Position three cables (5) on positive (+) nylon stud of Battery B, and two cables (5) on positive
(+) stud of Battery A. Secure with nylon stud nuts (3 and 4).
3.
Position one cable (8) on negative (-) nylon stud of Battery B and two cables (8) on negative (-)
stud of Battery A. Secure with nylon stud nuts (6 and 7).
4.
Position lid (2) on battery box and secure with four wing nuts (1).
5.
On electrical control box, switch ELECTRIC toggle to ON position.
6.
Ensure electrical power is on by viewing the voltage meter or by pushing the push switch on
the electrical control box for approximately 2 seconds, activating the hydraulic pump.
7.
On electrical control box, switch ELECTRIC toggle to OFF position.
0050 00-2