TB 5-2520-551-24
HYDRAULIC LINES (cont.)
186. Tighten union (item 113, AN815-12D) on generator pump low pressure return
flex hose (item 100, C5122512-2) using 12" adjustable wrench and 1-1/4"
combination wrench.
Hold union (item 113, AN815-12D) connected to generator pump low pressure
return hose (item 100, C5122512-2) using 12" adjustable wrench.
188. Position protective sleeve (item 55, C5131118-2) over tandem pump case
drain line (item 106, C5111OO8-1). Slide sleeve up hose until top of
sleeve is positioned just below channel bracket (item 6, C5110651-1). Trim
Using 1/4" flat tip screwdriver, tighten hose clamp
sleeve as necessary.
(item 59, AN737TW30) securing protective sleeve (item 55, C5131118-2).
189. Connect union (item 115, AN815-8D) to tandem pump case drain flex hose
(item 98, C5122511-1) and tighten using 12" adjustable wrench while holding
flex hose (item 98, C5122511-1) using 7/8" combination wrench.
190. Connect tandem pump case drain line (item 106, C5111OO8-1) onto union (item
115, AN815-8D) and tighten using 7/8" combination wrench. Hold union (item
115, AN815-8D) connected to tandem pump case drain flex hose (item 98,
C5122511-1) using 12" adjustable wrench.
191. Position protective sleeve (item 54, C5131118-1) over A/C pump sense line
(item 11O, C5111012-1). Slide sleeve up hose until top of sleeve is
positioned just below channel bracket (item 6, C5110651-1). Trim sleeve as
necessary.
Using 1/4" flat tip screwdriver, tighten hose clamp (item 58,
AN737TW22) securing protective sleeve (item 54, C5131118-1).
192. Connect union (item 114, AN815-4D) to A/C pump sense flex hose (item 95,
C5122508-1) and tighten using 12" adjustable wrench while holding flex hose
(item 95, C5122508-1) using 9/16" combination wrench.
193. Connect A/C pump sense line (item 110, C5111012-1) onto union (item 114,
AN815-4D) and tighten using 9/16" combination wrench. Hold union (item
114, AN815-4D) connected to A/C pump sense flex hose (item 95, C5122508-1)
using 12" adjustable wrench.
194. Position protective sleeve (item 55, C5131118-2) over A/C pump high
pressure line (item 109, C5111011-1). Slide sleeve up hose until top of
sleeve is positioned just below channel bracket (item 6, C5110651-1). Trim
sleeve as necessary.
Using 1/4" flat tip screwdriver, tighten hose clamp
(item 59, AN737TW30) securing protective sleeve (item 55, C5131118-2).
195. Connect A/C pump high pressure line (item 109, C5111011-1) onto flex hose
(item 96, C5122509-1) and tighten using 1" combination wrench while
holding A/C pump high pressure flex hose (item 96, C5122509-1) using 12"
adjustable wrench.
hose (item 99, C5122512-1) and tighten using 12" adjustable wrench while
51