TM 9--2520--215--34
0047 00--6
OUTPUT REDUCTION GEAR OUTPUT SHAFT AND RELATED PARTS REPAIR
CONTINUED
0047 00
ASSEMBLY Continued
WARNING
Dry--cleaning solvent used to clean parts in potentially dangerous to personnel and property.
Do not use near open flame or excessive heat. Flash point of dry--cleaning solvent is 138
degrees F.
Compress air used for cleaning purposes will not exceed 30 psi. Use only with effective
chip--guarding and personal protective equipment (goggles/shield, gloves, etc,).
6. Completely clean selected studs (10) by washing in dry--cleaning solvent. Blow--dry with compressed air.
7. Carefully examine threads of studs (10) for presence of burrs, nicks and foreign material. Repair defects found.
8. Apply moderate coating of clean International Comp.Stud Driving Lubricant to threads of studs (10) and tapped
holes in shaft.
9. Insert studs (10) in output shaft assembly (1) flange. Finish driving studs (10) to proper setting heights using stud
driving tool set to 320 lb--ft.
1
XT---1410---4 TRANSMISSION
10