TM 9--2520--215--34
0047 00--7
OUTPUT REDUCTION GEAR OUTPUT SHAFT AND RELATED PARTS REPAIR
CONTINUED
0047 00
ASSEMBLY Continued
WARNING
Dry--cleaning solvent used to clean parts in potentially dangerous to personnel and property.
Do not use near open flame or excessive heat. Flash point of dry--cleaning solvent is 138
degrees F.
Compress air used for cleaning purposes will not exceed 30 psi. Use only with effective
chip--guarding and personal protective equipment (goggles/shield, gloves, etc,).
10. On the XT--1410--4A transmission, check stud driving torque when fully inserted. If torque is less than 75 lb--ft or
more than 320 lb--ft, stud (10) must be removed by backing out or driving out. Thoroughly clean tapped holes and
studs by washing in dry--cleaning solvent. Blow--dry with compressed air.
NOTE
Quality control will review condition of both threads and recheck pitch diameters and minor
diameter of tapped hole before another stud is driven. When reason of out of limit torque has
been established and deficiency corrected, another stud may be driven. In additional to normal
inspection of shaft assemblies at final inspection station, procedure must be witnessed by
processing inspector on at least one shaft assembly each day and stud driving torques must be
rechecked.
XT---1410---4 TRANSMISSION
10